SRY2 SRY2-3 SRY4 Tubular Electric Heater

The working voltage shall not exceed 1.1 times its rated voltage, and the shell must be effectively grounded.

The dimension ”B” in the figure must be fully immersed in oil (and checked regularly) to avoid burning. The heated oil should be free of corrosive gases.

3. The mounting hole size of this electric heater is Φ65mm.

4. This model heater is designed according to the JB2379-78 flowing oil standard, with a surface load of 2-3.8 W/cm².

5. When selecting, the heating size should be determined based on the actual size of the heating medium.

Note: This heater can be used directly in combination with SRY2 and SRY4 models.

Rated voltage: Single-phase 220V, Three-phase 380V

Working medium: Mineral